Agilent Technologies, Inc. 45 SATA PHY, TSG & OOB Test MOI v.1.1 Revision 1.4
Test Procedure:
This parameter is covered by Agilent Technologies, Inc. N5411B automated SATA compliance software,
revision 1.02 or later. Either PASSor FAIL” is shown for the OOB Signal Detection Threshold test in
the report generated at the completion of the testing.
To execute this test on a products which supports ONLY 1.5Gb/s, an OOB burst is issued to the products at
the following voltage threshold limits:
40mV (at this limit, the products is expected to NOT DETECT the OOB signaling)
210mV (at this limit, the products is expected to DETECT the OOB signaling)
To execute this test on a products which supports 3Gb/s or 6Gb/s, an OOB burst is issued to the products at
the following voltage threshold limits:
60mV (at this limit, the products is expected to NOT DETECT the OOB signaling)
210mV (at this limit, the products is expected to DETECT the OOB signaling)
When the 40mV of
differential OOB amplitude is
needed at the products
receiver, then insert the
8493C-020 20dB passive
attenuators here, one on each
of the 11636B power divider
outputs, before the SMA cable
is attached. The voltage
output of the 81134A after the
attenuator is now 10 times
lower than the voltage
selection on the 81134A
output. The sensitivity of the
adjustment is now 0.1mV
instead of 1mV with the
“divide-by-10” attenuator in
place.