Agilent Technologies, Inc. 35 SATA PHY, TSG & OOB Test MOI v.1.1 Revision 1.4
This parameter is covered by Agilent Technologies, Inc. N5411B automated SATA compliance software,
revision 1.02 or later. Either “PASS” or “FAIL” is shown for the 6Gb/s TJ test in the report generated at
the completion of the testing.
Observable Results:
• RJ measured (RJ
meas
) at a maximum of 0.18 UI into a Laboratory Load before the Compliance Interconnect
Channel (CIC) when measured using the specified JTF (for products running at 6Gb/s) (Informative Only)
• TJ measured at a maximum of (RJ
meas
) + 0.34 UI into a Laboratory Load before the CIC when measured
using the specified JTF (for products running at 6Gb/s) (Informative Only)
• TJ measured at a maximum of (RJ
meas
) + 0.34 UI into a Laboratory Load after the CIC when measured
using the specified JTF (for products running at 6Gb/s) (Informative Only)
• TJ values at 10E-6 and 10E-12 measured at a maximum of 0.46 UI and 0.52 UI respectively into a
Laboratory Load after the CIC when measured using the specified JTF (for products running at 6Gb/s)
Possible Problems:
Some products may not support disconnect during the process of enabling BIST and testing. For these
products, refer to the Disconnect sections of reference [5] for setup requirement.