Wilder Technologies SATA 2.5 Test Adapter Especificaciones Pagina 39

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 87
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 38
Agilent Technologies, Inc.
Agilent Technologies, Inc. 39 SATA PHY, TSG & OOB Test MOI v.1.1 Revision 1.4
Test Setup:
1. The N5411B SATA compliance software will prompt for LBP when needed. When prompted, follow
the procedures in reference [5] to enable those BIST-TAS patterns. Or keep products in BIST-L.
2. Plug the test fixture into the products. The test fixture is connected to channels 1 and 3 of the scope by
two 36” SMA cables (Rosenberger or equivalent). OBSERVE the signal on the scope. If it is correct, press
OK in the N5411B prompt. If not, the products did not properly handle BIST Activate FIS; a non-standard
way to make it produce the desired pattern will be required.
Test Procedure:
This parameter is covered by Agilent Technologies, Inc. N5411B automated SATA compliance software,
revision 1.02 or later. Either PASSor FAIL” is shown for the 6Gb/s Transmitter Minimum Amplitude
test in the report generated at the completion of the testing.
Observable Results:
The 6Gb/s transmitter differential amplitude shall be greater than or equal to 240mVpp.
Possible Problems:
Some products may not support disconnect during the process of enabling BIST and testing. For these
products, refer to the Disconnect sections of reference [5] for setup requirement.