Agilent Technologies, Inc.
Agilent Technologies, Inc. 61 SATA PHY, TSG & OOB Test MOI v.1.1 Revision 1.4
A picture of the Crescent Heart Software TF-SATA-NE/ZP or TF-eSATA-NE/ZP test adapter or equivalent is
shown below for reference. The TF-SATA-NE/ZP has four SMA(f) connectors labeled appropriately to connect to
Host TX+ (HT+), Host TX- (HT-), Host RX+ (HR+) and Host RX- (HR-). Information about the Crescent Heart
Software test fixtures can be obtained from their website at:
http://www.c-h-s.com/tf-sata.shtml
The Agilent Technologies N5421A Receptacle and Plug test fixtures are shown below for reference. The fixtures
have four SMA(f) connectors and a power supply connector. Information about Agilent test fixtures can be found at:
www.agilent.com/find/sata
NOTE: The SATA cable end connector on the fixture is fragile. Support the cables connected to the fixture during
connection, testing and disconnect. Do not let their weight be supported by torque on the SATA connector. When
unplugging the fixture between tests, grasp the sides of the SATA connector, not the PCB mated to the SATA
connector. The easiest way to set up the cables and test fixture for testing is to loosely connect all SMA connectors
to the test fixture prior to aligning the SATA connector to the product’s SATA connector, then tighten the SMA
connections using wrenches once the proper alignment of the SATA connectors is achieved. This will prevent
damage to the test connector, and help to ensure a longer life for this sensitive test fixture.
Information about the ULINK Technology, Inc. DriveMaster 2008 and 2010 software can be obtained from their
website at:
http://www.ulinktech.com