Agilent Technologies, Inc.
Agilent Technologies, Inc. 47 SATA PHY, TSG & OOB Test MOI v.1.1 Revision 1.4
Example Typical products behavior for out of specification COMINIT/COMRESET sequence at 40mV or
60mV
Observable Results:
Verify that the products consistently response to each COMINIT/COMRESET sequence under the
following sequence parameters:
6 x (COMINIT/COMRESET burst + 480UI gap)
+1 x (45,000UI gap)
Verify that the products respond consistently to each COMINIT sequence when voltage threshold is
changed to 210mV
Verify that the products does not respond consistently when voltage threshold is changed to 40mV (Gen1
only) or 60mV (Gen 2 or Gen3)
Pass/Fail Criteria
• For products running at 1.5Gb/s ONLY:
o Verification of NO products OOB detection at 40mV
o Verification of products OOB detection at 210mV
o If any of the above cases fails, this is considered a failure by the products.
• For products running at 3Gb/s or 6Gb/s:
o Verification of NO products OOB detection at 60mV
o Verification of products OOB detection at 210mV
o If any of the above cases fails, this is considered a failure by the products.