Agilent Technologies, Inc. 36 SATA PHY, TSG & OOB Test MOI v.1.1 Revision 1.4
Test TSG-14 - Gen3 (6.0Gbps) Transmitter Maximum Differential
Voltage Amplitude
Purpose: To verify that the Maximum Amplitude of the product’s transmitter is within the conformance limits.
References:
[1] Serial ATA Revision 3.0, 7.2.1, Table 31 – Transmitted Signal Requirements
[2] Ibid, 7.2.2.2.7
[3] Ibid, 7.4.3, 7.4.5
[4] SATA Interoperability Program Unified Test Document, 2.15.14 Gen3 (6Gb/s) Maximum
Differential Voltage Amplitude
[5] Pre-Test MOI
Resource Requirements:
Same as for TSG-01.
See appendix A for details.
Last Template Modification: March 25, 2009 (Version 1.02)
Discussion:
Reference [1] specifies the Transmitted Signal conformance limits for SATA products. The maximum
differential amplitude shall be measured at the TX Compliance point into a Lab Load. A Gen3 MFTP shall
be used for this compliance measurement. The MFTP will contain emphasis due to its run length, if the
transmitter supports this signal conditioning, and allows for simple edge triggering for the signal capture.
The maximum amplitude is defined as the peak to peak value of the average of 500 waveforms
measured over a time span of 4 Gen3 UI, using the HBWS. Reference [2] provides the definition of this
term for the purposes of SATA testing. Reference [3] defines the measurement requirements for this test.
This test requirement is only applicable to products running at 6Gb/s.
Peak-to-Peak Voltage Measurement of 500 Time-Averaged acquisitions of 4 consecutive MFTP UI
Test Setup: