Agilent Technologies, Inc.
Agilent Technologies, Inc. 44 SATA PHY, TSG & OOB Test MOI v.1.1 Revision 1.4
TX+ signal that will be delivered to the RX+ input on the products. The remaining 81134A data outputs,
Channel 1 negative (-) and Channel 2 positive (+) are mixed together and delivered to the RX- input on the
products through the Crescent Heart Software TF-SATA-NE/ZP or TF-eSATA-NE/ZP test adapter or
equivalent.
The OOB Tests are designed to be run concurrently for simplicity. Since the initiation of a COMRESET
from a products or pattern generator will force a hard reset in a products, the following OOB tests can all be
performed using an Agilent 81134A 3.35Gbps Programmable Pulse/Pattern Generator to generate the
nominal OOB COMRESET and COMWAKE bursts, as well as to stress the minimum and maximum
voltage threshold conditions for OOB Signal Detections. The Agilent Infiniium oscilloscope, which is
running the N5411B SATA test software, will control the pattern generator stimulus as well as the
oscilloscope acquisition and processing parameters, providing fully automated control and repeatability of
the OOB test sequence in successive fashion. A COMRESET is issued from the generator prior to running
each test to ensure products reset, but in some cases, it may still be necessary to remove power from the
products under test temporarily to allow the products to exit from a BIST controlled mode and return to
normal operation.
Example OOB Setup for a SATA Device:
The N5411B software includes a calibration routine to verify the amplitudes for the OOB bursts used to test
OOB minimum threshold detection amplitude at 40mV and 210mV for Gen1 products and 60mV and
210mV for Gen2 or Gen3 products.
CH1
CH
CH
DRIVE
(DUT)
\
\
\
\
20dB Attenuators
Power Divider
DC
Blockers